首页 服务支持可靠性测试
可靠性测试
我们全面的测试能力确保产品的可靠性远超国际标准,测试项目均经过 CNAS 认可。
序号类型测试项目参考标准设备主要参数CNAS
1High Temperature Exposure (Storage)

High Temperature

Exposure (Storage)

AEC-Q200-Rev E March 20, 2023

MIL-STD-202-108, 2015

High Temperature 

Tester Chamber

High Frequency LCR Tester
Milliohm Meter
1. Temperature range: +85°C ~ +250°C
2. Box internal dimensions: (W) 600mm × (H)500mm × (D) 500mm
Certificated
2

Low Temperature

test

GB/T 2423.1-2008Medical Cryopreservation Box
 High Frequency LCR Tester
 Milliohm Meter
1. Temperature ≥-86°C
2. Maximum space: (W) 470mm × (H) 450mm ×(D) 480mm
3. Only test: Test Ab
Certificated
3

Temperature

Cycling

AEC-Q200-Rev E March 20, 2023

JESD22-A104F.01, 2023

MIL-STD-202-107, 2015
Thermal Shock Test Chamber
High Frequency LCR Tester
Milliohm Meter
1. Temperature range: -60°C ~ +150°C
2. Box internal dimensions: (W) 500mm × (H)400mm × (D) 400mm
Certificated
4Humidity Bias

AEC-Q200-Rev E March 20, 2023

JESD22-A104F.01, 2023

MIL-STD-202-107, 2015

Constant Temp & Hum 

Test Chamber

High Frequency LCR Tester
Milliohm Meter
1. The internal size of the box: (W) 600mm× (H)600mm×(D) 500mm

2. Temperature test range: -40°C ~ +150°C,

3.  Humidity range: 85%RH~95%RH

Certificated
5Salt spray test

GB/T 10125-2021

MIL-STD-202-101, 2015
Salt Spray Tester
Precision Electronic Scales
Magnifiers
Conductivity Tester
Maximum space: (W) 600mm × (H) 450mm ×(D) 400mmCertificated
6

High Temperature

Operating  Life

AEC-Q200-Rev E March 20, 2023
MIL-STD-202-Method108
DC Power Supply

High Temperature 

Tester Chamber

High Frequency LCR Tester
Milliohm Meter
1. Temperature range: +85°C ~ +250°C

2. Box internal dimensions: 

(W) 600mm × (H)500mm × (D) 500mm

Certificated
7MechanicalBoard Flex (SMD)AEC-Q200-005 REV A June 1,2010
AEC-Q200-Rev E March 20, 2023
Tensile Strength Tester
High Frequency LCR Tester
Milliohm Meter
Reflow Oven
Force value less than 1kNCertificated
8Terminal Strength (Axial)AEC-Q200-Rev E March 20, 2023
AEC-Q200-006 REV A June 1,2010
Tensile Strength Tester
High Frequency LCR Tester
Milliohm Meter
Reflow Oven
Force value less than 1kNCertificated
9

Resistance to

Soldering Heat

Resistance to Soldering HeatAEC-Q200-Rev E March 20, 2023
MIL-STD-202-210, 2015
High Frequency LCR Tester
Milliohm Meter
Reflow Oven
Temperature range: 100°C~350°CCertificated
10SolderabilityAEC-Q200-Rev E March 20, 2023
J-STD-002E, 2017
Tin Furnace
Steam Aging Tester
Magnifiers
1. 4.2.4 test D;
2. 4.2.6 Test A;
3. 4.2.7 Test B;

4. Box internal size: 

(W) 160mm×(H)110mm×(D) 45mm

Certificated
11

Resistance to

Solvents

Resistance to

Solvents

AEC-Q200-Rev E March 20, 2023
MIL-STD-202-215, 2015
Electronic Timer

High Precision 

One-piece Constant

Temperature Hot 

Plate 

Magnifiers 
/Certificated
12

Physical

Dimension

AEC-Q200-Rev E March 20, 2023
JESD22-B100B, 2003
Digital CalipersMeasurement only, the workpiece size is less                            than 121.8mmCertificated
13External Visual

AEC-Q200-Rev E March 20, 2023

MIL-STD-883-2 w/CHANGE1,2022                                             
Magnifiers/Certificated