Item | Category | Test Items | Reference Standards | Equipment | Key Spec. | CNAS |
|---|---|---|---|---|---|---|
| 1 | High Temperature Exposure (Storage) | High Temperature Exposure (Storage) | AEC-Q200-Rev E March 20, 2023 MIL-STD-202-108, 2015 | High Temperature Tester Chamber High Frequency LCR TesterMilliohm Meter | 1. Temperature range: +85°C ~ +250°C 2. Box internal dimensions: (W) 600mm × (H) 500mm × (D) 500mm | Certificated |
| 2 | Low Temperature test | GB/T 2423.1-2008 | Medical Cryopreservation Box High Frequency LCR TesterMilliohm Meter | 1. Temperature ≥-86°C 2. Maximum space: (W) 470mm × (H) 450mm × (D) 480mm 3. Only test: Test Ab | Certificated | |
| 3 | Temperature Cycling | AEC-Q200-Rev E March 20, 2023 JESD22-A104F.01, 2023 MIL-STD-202-107, 2015 | Thermal Shock Test Chamber High Frequency LCR Tester Milliohm Meter | 1. Temperature range: -60°C ~ +150°C 2. Box internal dimensions: (W) 500mm × (H) 400mm × (D) 400mm | Certificated | |
| 4 | Humidity Bias | AEC-Q200-Rev E March 20, 2023 JESD22-A104F.01, 2023 MIL-STD-202-107, 2015 | Constant Temp & Hum Test Chamber High Frequency LCR Tester Milliohm Meter | The internal size of the box: (W) 600mm × (H)600mm × (D) 500mm Temperature test range: -40°C ~ +150°C, Humidity range: 85%RH~95%RH | Certificated | |
| 5 | Salt spray test | GB/T 10125-2021 MIL-STD-202-101, 2015 | Salt Spray Tester Precision Electronic Scales Magnifiers Conductivity Tester | Maximum space: (W) 600mm × (H) 450mm × (D) 400mm | Certificated | |
| 6 | High Temperature Operating Life | AEC-Q200-Rev E March 20, 2023 MIL-STD-202-Method108 | DC Power Supply High Temperature Tester Chamber High Frequency LCR TesterMilliohm Meter | 1. Temperature range: +85°C ~ +250°C 2. Box internal dimensions: (W) 600mm × (H) 500mm × (D) 500mm | Certificated | |
| 7 | Mechanical | Board Flex (SMD) | AEC-Q200-005 REV A June 1,2010 AEC-Q200-Rev E March 20, 2023 | Tensile Strength Tester High Frequency LCR Tester Milliohm Meter Reflow Oven | Force value less than 1kN | Certificated |
| 8 | Terminal Strength (Axial) | AEC-Q200-Rev E March 20, 2023 AEC-Q200-006 REV A June 1, 2010 | Tensile Strength Tester High Frequency LCR Tester Milliohm MeterReflow Oven | Force value less than 1kN | Certificated | |
| 9 | Resistance to Soldering Heat | Resistance to Soldering Heat | AEC-Q200-Rev E March 20, 2023 MIL-STD-202-210, 2015 | High Frequency LCR Tester Milliohm Meter Reflow Oven | Temperature range: 100°C~350°C | Certificated |
| 10 | Solderability | AEC-Q200-Rev E March 20, 2023 J-STD-002E, 2017 | Tin Furnace Steam Aging Tester Magnifiers | 1. 4.2.4 test D; 2. 4.2.6 Test A; 3. 4.2.7 Test B; 4. Box internal size: (W) 160mm × (H) 110mm × (D) 45mm | Certificated | |
| 11 | Resistance to Solvents | Resistance to Solvents | AEC-Q200-Rev E March 20, 2023 MIL-STD-202-215, 2015 | Electronic Timer High Precision One-piece Constant Temperature Hot PlateMagnifiers | / | Certificated |
| 12 | Physical Dimension | AEC-Q200-Rev E March 20, 2023 JESD22-B100B, 2003 | Digital Calipers | Measurement only, the workpiece size is less than 121.8mm | Certificated | |
| 13 | External Visual | AEC-Q200-Rev E March 20, 2023 MIL-STD-883-2 w/CHANGE1,2022 2 | Magnifiers | / | Certificated |